High-Performance Alternative to Harmonic Ligasure Devices
✔7 mm Vessel Sealing: Permanent occlusion of large vessels & bundles without clips or sutures.
✔High Burst Pressure (>360 mmHg): Exceeds 3× systolic pressure for reliable post-op safety.
✔Minimal Thermal Spread (<2 mm):Prevents collateral damage to adjacent nerves & vital organs.
✔Anti-Stick & Low Smoke: Clean endoscopic visual field with minimal tissue carbonization.
✔Versatile Tool Support: Fully compatible with SM handles, QEB 5mm & QF scissor electrodes.
Product Detail

Vessel Sealing and Cutting System: Advanced Electrosurgical & Vessel Sealing Technology

High-Performance Alternative to Harmonic Ligasure Devices for 7mm Vessel Ligation & Hemostatic Transection

Harmonic ligasure devices - Vessel Sealing and Cutting System

The Vessel Sealing and Cutting System by Qianjing Medical is an intelligent advanced energy solution engineered for precise electrocoagulation, secure vessel sealing, and mechanical cutting during open and laparoscopic surgeries. Tailored to meet the clinical efficacy expected from premium harmonic ligasure devices, our electrothermal system reliably closes and transects vascular bundles up to 7 mm in diameter.

Compatible with modern high-frequency vascular closure systems, electrosurgical units, and comprehensive energy platforms, this system offers minimal lateral thermal spread and dependable hemostasis. It is the trusted choice for public general hospitals, surgical oncology centers, and international healthcare tenders seeking high-durability surgical energy equipment with superior clinical cost-effectiveness.

Harmonic Ligasure Device Machine in Surgery: Key Product Advantages

✔
Reliable 7 mm Vessel Occlusion: Capable of permanently sealing blood vessels and tissue bundles up to 7 mm in diameter in a single activation cycle.
✔
High Burst Pressure Resistance: The sealed vascular zone withstands more than 3 times normal human systolic pressure (exceeding 360 mmHg), ensuring superior post-op safety.
✔
Minimal Lateral Thermal Damage: Features precise energy confinement with transverse thermal damage restricted to <2 mm, protecting adjacent critical anatomical structures and nerves.
✔
Clear Visual Field & Fast Sealing: Rapid energy delivery produces minimal surgical smoke, maintaining optimal endoscopic clarity while eliminating foreign body implants (clips/sutures).
✔
Anti-Adhesion & Non-Carbonizing: Smooth jaw surface design prevents tissue adherence and eschar buildup, significantly decreasing blood loss, procedural duration, and patient hospitalization time.

Surgical Applications Across Key Specialties

Thoracic & Bariatric

  • Lobectomy, Esophagectomy

  • Sleeve Gastrectomy, Gastric Bypass

Gastrointestinal & HPB

  • Gastrectomy, Colectomy, Appendectomy

  • Hepatectomy, Splenectomy, Pancreaticoduodenectomy

Gynecology & Urology

  • Total / Subtotal Hysterectomy, Salpingo-oophorectomy

  • Prostatectomy, Cystectomy, Partial / Radical Nephrectomy

Generator Specifications (Model: SM5000)

Product NameVessel Sealing and Cutting System
Specification / ModelSM5000
Rated Output PowerBipolar Coag: 180W / 100Ω | Bipolar Cut: 100W / 300Ω
Power Supply220V / 110V ± 22V; 50Hz ± 1Hz
Working ConditionsTemperature: 10°C ~ 40°C; Humidity: 30% ~ 75%
Atmospheric Pressure700 hPa ~ 1060 hPa
Weight14 kg
Unit Dimension480mm (L) × 400mm (W) × 140mm (H)
Package Dimension550mm (L) × 550mm (W) × 340mm (H)

Instruments & Surgical Electrodes Specifications

Table 1: SM Series Vessel Sealing Handpieces

ModelClosed Length (mm)Cutting Length (mm)Outer Dia. (mm)Effective Length (mm)Cable Length (mm)Jaw Type
SM11002119103702800Straight tip
SM12002119102002800Straight tip
SM1500181653702800Straight tip
SM1500W222053702800Curve tip
SM1520181652002800Straight tip
SM1520W222052002800Curve tip
SM1544181654402800Straight tip
SM1544W222054402800Curve tip
SM21502119—Open Surgery2800Curve tip

Table 2: Basic Dimensions of QEB Type Surgical Electrode (Unit: mm)

SNSpecification & ModelOuter Rod Dia. (φD)Working Length (L1)ToleranceCable Length (L2)ToleranceFit Trocar Dimension
1QEB5L235230±10%30000 ~ -10%5
2QEB5L37370
3QEB5L44440

Table 3: Basic Dimensions of QF Type Surgical Electrode (Scissor-Type, Unit: mm)

SNModel NumberWorking Length (L1)ToleranceCable Length (L2)Tolerance
1QF1212190±10%30000 ~ -10%

※ For additional shaft configurations, OEM customization, and custom cable connectors, please refer to the product manual. Specifications are subject to ongoing clinical refinement.

Frequently Asked Questions (FAQ)

Q1: How does this vessel sealing system compare with harmonic ligasure devices?

A: While traditional ultrasonic harmonic scalpels excel in fine dissection and thin vessel transection up to 5mm, our advanced electrothermal vessel sealing and cutting system utilizes pulsed bipolar energy and optimized pressure feedback to reliably seal larger vessels and vascular bundles up to 7 mm with a burst pressure rating exceeding 360 mmHg. It provides the sealing security comparable to LigaSure technology with low smoke and minimal thermal spread.

Q2: Can the instruments be matched with third-party electrosurgical generators?

A: Yes. In addition to our dedicated SM5000 generator, our handpieces feature standardized connection cables that can be adapted to mainstream high-frequency generators and hospital surgical energy platforms, facilitating seamless integration for international hospital procurement.

Q3: Do you provide OEM/ODM and documentation for national tenders?

A: Qianjing Medical offers complete technical documentation, CE / ISO 13485 certifications, test verification reports, and customized OEM/ODM services to support regional distributors and public healthcare tender submissions.

Equip Your Operating Rooms with Next-Generation Energy Platforms

High burst pressure, 7mm reliable closure, and minimal lateral damage. Contact our engineering and sales specialists for technical brochures and tender quotations.

Request a Quote & Demo

20+ Years Excellence | CE & ISO Certified | Global Hospital Tender Support

Related news
Inquire Now
Name: *
Mobile:
E-mail: *
Message: *
Verification code: *
  
Other products
Hot products